LK-081 measuring head/sensor head
Measuring heads Standard type sensor head
Referenzabstand
80 mm
Measuring range
±15 mm
Light source
Type
Visible red semiconductor laser
wavelength
670 nm
Output radiation
0,95 mW
Laser
Class
FDA (CDRH) Part 1040.10
2nd grade
IEC 60825-1
Light spot diameter
(at reference distance)
Ca. 70 µm
Linearity
±0.1% v.E. *1
Repeatability
3 µm*2
Analog output
Voltage output
±5 V (3 µm/mV)*3
Impedance
100 O
Current output
4 to 20 mA (load: max. 350 O)
Alarm output
NPN: max. 100 mA (max. 40 V) (Ruhekontakt) Restspannung max. 1 V
Sampling cycle
1.024 µs
More functions
AUTO ZERO, response selection, offset/span adjustment, hold output in alarm condition
Temperature properties
0.01% v.E./°C
Nominal values
Supply voltage
24 VDC ±10%, ripple (S-S) 10% or less
Maximum power consumption
max. 400 mA
Environmental resistance
Protection class
IP67
Ambient light
Incandescent or fluorescent lamp: max. 10,000 lux
Ambient temperature
0 to +50 °C (no condensation)
Relative humidity
35 to 85% RH (No Condensation)
Vibration resistance
10 to 55 Hz, double amplitude 1.5 mm, 2 hours each in the X, Y and Z directions
Material
Die-cast aluminum
Weight
Approx. 385 g (including cable)
LK-081 measuring head/sensor head
Measuring heads Standard type sensor head
Referenzabstand
80 mm
Measuring range
±15 mm
Light source
Type
Visible red semiconductor laser
wavelength
670 nm
Output radiation
0,95 mW
Laser
Class
FDA (CDRH) Part 1040.10
2nd grade
IEC 60825-1
Light spot diameter
(at reference distance)
Ca. 70 µm
Linearity
±0.1% v.E. *1
Repeatability
3 µm*2
Analog output
Voltage output
±5 V (3 µm/mV)*3
Impedance
100 O
Current output
4 to 20 mA (load: max. 350 O)
Alarm output
NPN: max. 100 mA (max. 40 V) (Ruhekontakt) Restspannung max. 1 V
Sampling cycle
1.024 µs
More functions
AUTO ZERO, response selection, offset/span adjustment, hold output in alarm condition
Temperature properties
0.01% v.E./°C
Nominal values
Supply voltage
24 VDC ±10%, ripple (S-S) 10% or less
Maximum power consumption
max. 400 mA
Environmental resistance
Protection class
IP67
Ambient light
Incandescent or fluorescent lamp: max. 10,000 lux
Ambient temperature
0 to +50 °C (no condensation)
Relative humidity
35 to 85% RH (No Condensation)
Vibration resistance
10 to 55 Hz, double amplitude 1.5 mm, 2 hours each in the X, Y and Z directions
Material
Die-cast aluminum
Weight
Approx. 385 g (including cable)